Operating Limits:
Liquid temperature:
Normal temperature range +15℃~+70℃
Hot water range + 70℃ ~105℃
Max. ambient temperature: +40℃
Max. operation pressure: 10 bar
Max. inlet pressure is limited by max. operation pressure.
Continuous duty
Motor:
T.E.F.C. continuous
Voltage: 50Hz: 1x220~240V
3x220~240V/380~415V
Insulation class: F
Protection: IP55
Single-phase motor with built-in thermal protector
Material:
Thin, clean, non-flammable and non-explosive liquid
containing no solid granules and fibers. Mineral water,
soft water, pure water, edible vegetable oil and other
light chemical mediums. When density or viscosity of
the liquid is higher than that of water.
Whether the pump is suitable to convey the liquid
depends on many factors, among which the most
important ones are chlorine content, PH value,
temperature, solvent and oil content.
Application:
These series are primarily designed for the industrial purpose:
Water treatment processes
Industrial cleaner and dishwasher
Water boosting on process
Heating and cooling for industrial process
Air-conditioning system
Air heating, heating device (soft water)
Water supply and boosting (drinking water, light chlorine water)
Fertilization/metering system
Other specific applications